Following ISO 13207-1

Coil Data

Operating Voltage: 20,5 ÷ 30V
Direction Indicator Range Power Rating: Min 1W @18V - Max 8W @ 30V
Rated Voltage: 24V DC
Num Terminals: 4

Contacts Data

Max Continuous Current: 400 mA
Electrical Lifestime: 35000 hours Continuous
Electrical Lifestime Hazard Mode: 36h

Protections

Degree Protection: IP 65 DIN40050

Other Data

Storage Temperature: -40°C ÷ +80°C
Diagnostics: Present, a failure warning
Connection: Loose ADR Cables
Operating Temperature: -40°C ÷ 85°C
Test Temperature: + 23°C

Materials

Housing: PA 66 GF25
Cables: 210mm x 0,75mm² T2 300V DC 105°C
Resin Compound: Polyurethane black Black

Additional Data

In Conformity with: ISO 13207 "Led Lamp Characteristics for bulb compatible failure detection PART 1: Led lamps used as direction indicators"
Salt Spray Test: 96h @ 5% NaCl
Homologation Number: 10R-03 0926

Other products

information

You are asking for information for the product i-LS Units – ILS.02.H.
My Agile Privacy
This website uses technical and profiling cookies. Clicking on "Accept" authorises all profiling cookies. Clicking on "Refuse" or the X will refuse all profiling cookies. By clicking on "Customise" you can select which profiling cookies to activate.
Warning: some page functionalities could not work due to your privacy choices
Mao Mao
Mao Mao
Mao Mao
Mao Mao
Mao Mao
Mao Mao

Enter the OEM, ODM or major distributors codes to search for your product